16 A

The power track contains a 3-phase main supply group 16A, 400V with neutral and earth plus a 1-phase group priority supply group 16A, 230V with neutral and earth. The main group and the priority group have a common earth. The associated single phase and 3-phase socket outlets can be positioned anywhere along the power track. The power track is type approved for open location in dry areas at normal room temperature. Approval also applies without cover strip. The power track may be installed at any height on the wall, vertically, horizontally or in the ceiling.

DWP 16A can be completed with cable duct DWP Combi or DWP Connect if more space is needed

 

POWER TRACK UP TO 16A.

The outlets are built on 45x45mm modules and gives the opportunity for using both high and low current in the same unit. Choose up to 6 sockets in a single unit, installed within a minute. Prioritized outlets are intended for the 1-phase group. All outlets can be installed or removed without interrupting the Power.

The outlets on this page are suitable for Power Track 16A.

What is smart is hidden inside.

The DWP system power track contain one 3-phase group and one 1-phase group which means you are able to use both 1-phase and 3-phase outlets in the same track. Add or move an outlet can be done without cutting the power.
-Pretty brilliant!

EXEMPLE OF ACCESSORIES FOR DWP 16A.

Fixed angle 16A

Flexible angle 16A

Bracket 19mm

Connetcing box 16A, right

L-joint 16A

Cover strip IP20

EXEMPLE OF SOCKET OUTLETS FOR iZi 45 16A.

2-ways 1-phase socket outlet

4-ways 1-phase socket outlet

6-ways 1-phase socket outlet

DWP 16

DWP 16 OVERVIEW


POWER TRACK
Incl. 1 connecting piece. Installed on brackets.
The power track contains a 3-phase main supply group 16 A, 400 V with neutral and earth, and a single-phase priority supply group 16 A, 230 V with neutral and earth. The main group and the priority group have a common earth.
The associated single-phase and 3-phase socket outlets can be positioned anywhere along the power track. Type-approved for open location in dry areas at normal room temperature. Encapsulation IP20. Approval also applies without cover strip. Must be installed by qualified electrician. The track may be installed at any height on the wall, vertically or horizontally, or in the ceiling. It can also be installed in a suspended ceiling or in a computer room floor if it is easily accessible and clearly marked. The power track may also be used as a light fitting track with socket outlets for single-phase and 3-phase. The power track is supplied as standard in aluminum, white- painted shade RAL 9010 or nature. Cut lengths quoted on request.

MAINS CONNECTION BOX
Incl. 1 end fitting, 2 locking clamps.
Designed for direct connection in main group.
Area connecting stripes 5 x 4 mm2 + 3 x 4 mm2 for both solid and twisted cable. The box is non-perforated with space for drilling in bottom 2 x 20 mm, top- and downside 2 x 22.5 mm, end plate 2 x 22.5 mm.

L-JOINT
Incl. 1 connecting piece and 2 locking clamps.

T-JOINT
Incl. 2 connecting pieces, 1 end fitting, 1 locking clamps.
Other types quoted on request.

FIXED ANGLES
Incl. 2 connecting piece and 1 locking clamps. Cutting: minimum size 145x145mm.
Other types quoted on request.

FLEXIBLE ANGLES
Incl. 1 connecting piece and 2 locking clamps for single. 3 locking clamps for double.
Switched and reversed flexible angles quoted on request.

DWP Accessories Brackets Combi-Connect 19

Brackets

For DWP Power track with Combi or Connect media duct

Bracket 19 mm is used for wall and ceiling installation. Distance between the brackets max. 1200 mm or at least 2 per track/duct. For wall installation the bracket is mounted with the lug facing down.
In case of double installation the brackets are mounted with the lugs facing each other. Spacers are available.
Track/duct are clipped into position. At ends and by vertical installation locking clamps must be used to fix the track/duct.
Locking clamps are pushed into the U-slot in the track. To unclip the track/duct use a screwdriver

Download dimensions (zip): www.kb-system.com/byggmatt

DWP Accessories Brackets Combi-Connect 35

Brackets

For DWP Power track with Combi or Connect media duct

Bracket 35 mm is used for wall installations. Distance between the brackets max. 1200 mm or at least 2 per track/duct.
Spacers are available. Track/duct are clipped into position.

Download dimensions (zip): www.kb-system.com/byggmatt

DWP Accessories Brackets Connect

Brackets

For DWP Power track with Connect media duct
Wall bracket 46, 71 och 96 mm can also be used for installation of the Power track (without duct).

Wall brackets with ventilation louvre U/F-shape are used as upper bracket with extension from the wall.
Dimensions are 46, 71 or 96 mm. The distance between the brackets must be max. 1200 mm or at least 2 per track/duct.
In case of double installation the downward extension bracket is used as a lower bracket. Spacers, 2 mm or 3 mm, are available.
Wall- and downward extension brackets are self-locking. Adjustable wall bracket only for horizontal installation.

DWP Accessories Brackets Combi

Brackets

For DWP Power track with Combi media duct

Wall bracket with ventilation louvre U/F-shape is used with extension from wall when installing the combination power track/DWP Combi. Dimensions are 54 or 94 mm.
The distance between brackets max. 1200 mm or at least 2/track. Spacers, 2 or 3 mm, are available.
Wallbrackets are self-locking. Adjustable wall bracket only for horizontal installation.

DWP Accessories Brackets Ceiling Installation

Brackets

For ceiling installation

Joint support for installation in ceiling is used with screw, pendelum or wire and must be centrated over each joint of the power track.
Bracket for ceiling must be used in every end of a power track and where an additional fixing point is necessary. Max. length between
brackets is 1200 mm. The brackets are clipped on the power tracks/cable ducts and locked with the locking screw.
Max weight between two fixing points are 15 kg.
Art no 4399 and 9655 have press nut M10 for threaded bar and are used by pendelum installatiton and by installation together with cable basket.